Sterilization self-sealing bags for autoclave 150x250mm 100 pieces

Cod produs: 375237
90,00 Lei
Fast delivery
Delivery 24-48h
14-day returnsWarrantyDelivery 24-48h
💵 Cash on delivery🔒 Secure order
Quick:
1

Specifications

Packaging
100 buc
Material
Transparent laminated film
Dimensions
150x250mm
Quantity
100 pieces
Sterilization
121-134 ºC
Sterilization duration
30 minutes
Shelf life
2 months
Usage
Single-use

Ghiduri utile:Consumabile de tatuaj — lista completă și la ce folosescConsumabile pentru un studio de tatuaj: lista completă lunarăConsumabile de unică folosință pentru studioul de tatuaj: ghid complet

Presentation video

Guide & full description

Complete guide: Sterilization self-sealing bags for autoclave 150x250mm 100 pieces

These are sterilization pouches with self-adhesive tape, in a generous 150×250 mm format, supplied in an economical set of 100 pieces. They are made of white medical paper on one side and transparent laminated film (polyester or polypropylene) on the other, so you can always see what instrument is inside without opening the package. They are designed for tattoo studios and clinics that sterilize reusable instruments in an autoclave — grips, tubes, forceps, and other bulkier parts — and are also compatible with ethylene oxide sterilization. The self-sealing tape closes the pouch hermetically with a simple press, without a sealing machine.

How to use

  1. Clean and dry the instruments before packaging, then insert a single instrument (or a single disassembled set) per pouch — articulated instruments should be placed open or disassembled, and sharp tips protected.
  2. Press the pouch to remove all air from inside.
  3. Peel off the protective film from the adhesive tape and press the tape firmly over the open end for an airtight seal across the entire width.
  4. Place each pouch in the autoclave, avoiding direct contact with the metal tray of the sterilizer and without overlapping the pouches.
  5. Run the steam sterilization cycle at 121–134 °C, maximum 30 minutes — the parameters for which the product is approved.
  6. After the cycle, let the pouches cool in the sterilizer for 5–10 minutes; you can leave the door wide open to speed up cooling.
  7. Check the indicator impregnated in the paper: for steam, the color should have changed from pink to brown (for ethylene oxide, from blue to orange). If it has not changed, repackage in a new pouch and repeat the sterilization.
  8. Store the sealed pouches in a clean, dry place and open them only when using the instrument.

Tips from us

  • Write the sterilization date on each pouch immediately after the cycle, so you can rotate stock correctly and quickly identify packages approaching the expiration limit.
  • Choose the pouch size according to the instrument: the 150×250 mm format is the most spacious in the range, suitable for large grips, tubes, and complete sets; for small parts, a smaller pouch reduces waste.
  • Do not overfill the pouch — the instrument must fit loosely, otherwise you risk perforating the paper or compromising the seal at the corners.
  • Protect sharp tips before packaging, so they do not puncture the medical paper during handling.
  • Visually inspect each pouch before use: if the packaging is perforated, wet, or has come unsealed, the contents are no longer considered sterile.
  • For a high volume of clients, the set of 100 pieces significantly reduces the cost per sterilization compared to small packs — it's worth keeping a constant stock.
Warning: The pouches are strictly single-use: once opened or passed through a cycle, they are discarded and not re-sterilized. According to the manufacturer, sterility is maintained for up to 2 months after sterilization, but only on condition that the packaging remains intact, sealed, and properly stored — any damage voids sterility, regardless of the date. The color indicator confirms exposure to the sterilization process, it does not replace good practice: correct loading of the autoclave, pre-cleaned instruments, and adherence to cycle parameters. The use of sterile packaging for reusable instruments is a requirement of health regulations for tattoo studios.

Frequently asked questions

Do I need a sealing machine (sealer) for these pouches?

No. This is the main advantage of self-sealing pouches: they have a special adhesive tape covered by a removable film. You remove the film, press the tape over the open end, and the pouch closes airtight. A heat sealer is only needed for cut-to-size sterilization rolls, not for this type of pouch.

How do I know sterilization was successful?

Each pouch has two indicators impregnated in the paper: one for steam and one for ethylene oxide. For steam sterilization (121–134 °C), the indicator changes from pink to brown; for ethylene oxide (30–54 °C), from blue to orange. If after the cycle the color has not changed, the process did not run correctly — repackage the instrument in a new pouch and repeat the sterilization. The indicator confirms exposure to the process; for periodic validation of the autoclave, follow your equipment's protocol.

How long do instruments remain sterile in the pouch?

The manufacturer indicates sterility maintenance for up to 2 months after sterilization, with the essential condition that the packaging remains intact and sealed. A perforated, wet, or unsealed pouch no longer guarantees sterility, regardless of how much time has passed. That is why it is useful to note the date on each pouch and visually inspect the packaging before each use.

What instruments fit in the 150×250 mm size and how do I choose the right size?

The 150×250 mm (15×25 cm) format is the most generous, suitable for bulky instruments: large grips, tubes, forceps, and complete sets. The selection rule is simple: the instrument must fit loosely, with enough space so the paper is not stressed and the seal can be made across the entire width. If you frequently package small parts, combine this format with smaller pouches, so you don't waste the large format unnecessarily.

Can I put multiple instruments in the same pouch to save money?

It is not recommended — the characteristic of these self-adhesive pouches is to be used for a single product (or a single disassembled set). Articulated instruments must be inserted open or disassembled, and sharp tips protected, so that steam reaches all surfaces and the paper is not perforated. Overcrowding the pouch compromises both the efficiency of sterilization and the integrity of the packaging.

Can I reuse a pouch if it looks good after opening?

No. The pouches are strictly single-use: once opened or passed through a sterilization cycle, they are discarded. They cannot be sterilized a second time — the indicator has already changed, and the material and adhesive tape no longer provide the antibacterial barrier and airtight seal. The cost per piece in the set of 100 is anyway low compared to the risk of contamination.

Product description

Sterilization self-sealing bags for autoclave The self-sealing bags are made of a plastic for medical use, called transparent laminated film, which comes from a special polyester or polypropylene film and medical paper. The paper used is smooth on both sides, white in color and provides great anti-bacterial protection. They are used for sterilization with Autoclave and Ethylene Oxide. To check the effectiveness of the sterilization, they have two indicators impregnated in the paper, one for steam and another for ethylene oxide. Correct sterilization is certified by changing the color of the indicator. For steam sterilization, at a temperature of 121-134 º C, the color changes from pink to brown. For sterilization with ethylene oxide, at a temperature of 30-54 º C, the color changes from blue to orange. The duration of maintaining sterilization is 2 months from sterilization, provided the integrity of the packaging is maintained. The bags used once must be thrown away, because they cannot be sterilized a second time. The distinctive feature of self-adhesive bags is their use for a single product. It does not require the use of a sealing machine, because it has a special adhesive tape that hermetically closes the open end of the bag. When using these bags, the instruments must be opened or dismantled, and the sharp points protected. This type of packaging provides protection for chemical and biological contamination from the moment of sterilization, until the package is opened.1. Insert the instrument into the bag and press until all the air is removed from the bag;2. Seal the bag;3. Place each package in the sterilizer. Avoid any contact with the metal tray of the sterilization oven (or with a bag in the case of the steam sterilization process);4. This product is approved / created for use in the steam sterilization process (autoclave sterilization) at temperatures of 121-134 º C for a maximum of 30 minutes.5. Let the bags / packages cool down in the sterilizer for 5-10 minutes after the whole process. To speed up cooling, leave the sterilizer door wide open; The price is for a set of 100 pieces. Size: 150x250mm Self-sealing sterilization pouches sized 150x250mm are essential consumables for any tattoo studio or medical office using autoclaves for reusable instrument sterilization. Made from high-grade medical paper on one side and transparent plastic film on the other, these pouches allow content visualization without opening, quickly identifying needed instruments. The self-sealing system guarantees an airtight and secure closure without requiring additional sealing equipment. The integrated sterilization indicator changes color after the autoclaving process, visually confirming proper sterilization. The 150x250mm size is the most generous, suitable for bulkier instruments such as large grips, tubes, complete needle sets, and surgical instruments. The economic package contains 100 pieces, being ideal for daily studio use. The 100-piece quantity offers excellent value for high-volume studios, significantly reducing per-unit cost compared to smaller packages. Materials used comply with European sterilization standards and are compatible with steam autoclaves at temperatures up to 134 degrees Celsius. The pouches maintain instrument sterility for an extended period after autoclaving, as long as the packaging remains intact and sealed. Proper use of self-sealing pouches is a mandatory requirement for sanitary compliance and demonstrates the studio's professionalism toward client health. Frequently Asked Questions How does the self-sealing system work? The pouches have an adhesive strip protected by a peel-off film. After inserting instruments, remove the film and press the adhesive strip for an airtight, secure seal without additional equipment. What does the indicator color change indicate? The sterilization indicator changes color from light to dark after exposure to steam at the correct temperature, visually confirming the autoclaving process was properly performed. At what temperatures can they be used? The pouches are compatible with steam autoclaves at temperatures up to 134 degrees Celsius, covering all standard sterilization protocols used in tattoo studios. How long do instruments remain sterile in the sealed pouch? Instruments remain sterile as long as the pouch is intact and properly sealed. Under optimal storage conditions, sterility is maintained for up to 30 days. What instruments can be sterilized in the 150x250mm size? The 150x250mm size (15.0x25.0 cm) is suitable for instruments such as grips, tweezers, tubes, and needles. Choose the size based on instrument volume. Are they single-use? Yes, self-sealing pouches are strictly single-use. After opening the seal, the pouch must be discarded and instruments re-sterilized in a new pouch if not used immediately. Can I see the contents without opening the pouch? Yes, one side of the pouch is transparent plastic film allowing visualization of instruments inside without compromising sterility by opening. Are they compliant with European standards? Yes, the self-sealing pouches are manufactured according to European sterilization standards and approved for use in professional medical and cosmetic environments. How should unused pouches be stored? Store unused pouches in a dry place at room temperature, away from direct light and humidity. Avoid damaging the original packaging to maintain quality. Can they be used in fields other than tattooing? Yes, self-sealing pouches are universal and used in dental offices, cosmetic salons, micropigmentation, podiatry, and any field requiring instrument sterilization.

You might also like

Reviews

No reviews yet. Bought this product? Be the first to leave one.

You get 25 points for a review, 50 if you add a photo.