Sterilization indicator Autoclave 19mmx50m
Specifications
- Dimensions
- 19mmx50m
- Sterilization
- 121˚-134˚C
- Color
- Blue/Brown/Green
- Format
- Adhesive Tape
- Usage
- Package Sealing
- Composition
- Thermosensitive Substance
- Quantity
- 50m
Ghiduri utile:Consumabile de tatuaj — lista completă și la ce folosescConsumabile pentru un studio de tatuaj: lista completă lunarăConsumabile de unică folosință pentru studioul de tatuaj: ghid complet
Presentation video
Guide & full description
Complete guide: Sterilization indicator Autoclave 19mmx50m
The autoclave sterilization indicator tape is the consumable that visually confirms that your instrument packages have gone through a steam sterilization cycle at 121–134 °C: the stripes change color from blue to brown or green. It is a mandatory element of sterilization control in tattoo and piercing studios that work with reusable instruments, but it is equally suitable for medical, dental, or cosmetic instruments. The tape roll, 19 mm wide and 50 m long, provides hundreds of sterilization cycles at a very low cost per application.
How to use
- Clean and dry the instruments, then package them in sterilization pouches, cassettes, or instrument boxes, according to your usual procedure.
- Cut a piece of tape about 4–5 cm from the roll, containing at least 3 indicator lines.
- Attach the tape to the outside of the package — the adhesive sticks to any type of wrapping and also acts as a seal for the package.
- According to the instructions, you can also place a piece inside cassettes or instrument boxes, as well as inside the sterilizer.
- Run the complete autoclave cycle, at temperatures between 121 and 134 °C.
- At the end of the cycle, check each package: the stripes must have changed from blue to brown or green.
- If the color hasn't changed on a package, do not use the instruments from it — repackage, repeat sterilization, and check the autoclave's operation.
- Write the sterilization date on the tape or package to have a clear record for each batch.
Tips from us
- Use the tape for every sterilization cycle and on every package placed in the autoclave — hygiene protocol requires it, and only then you can verify each batch individually.
- Write the date directly on the tape piece with a marker: it makes batch traceability much easier during an inspection.
- Do not rely solely on the chemical indicator: periodically validate the autoclave with biological indicators as well, which confirm the actual destruction of microorganisms.
- Store the roll in a dry place, away from heat sources — the tape contains a heat-sensitive substance and should not be accidentally exposed to high temperatures before use.
- Calculate your consumption comfortably: at 10–15 cm of tape per package, the 50 m roll provides approximately 330–500 uses, meaning months for a studio with daily sterilizations.
Frequently asked questions
How do I know that sterilization has occurred?▾
The tape contains a heat-sensitive chemical that reacts to the combination of temperature and steam pressure in the autoclave. After a full cycle at 121–134 °C, the stripes change color from blue to brown or from blue to green, and the change is irreversible — providing you with a visual, documentable proof for each sterilized package.
Does the tape guarantee that the instruments are sterile?▾
Not absolutely. The chemical indicator confirms that the package was exposed to the correct sterilization parameters, but it does not directly measure the destruction of microorganisms. That is why protocols recommend that, in addition to the tape used for each cycle, the autoclave should be periodically validated with biological indicators as well. Together, the two methods give you complete control over sterilization quality.
Can I use this indicator also for a dry heat sterilizer?▾
No. This indicator is specifically designed for autoclaves, i.e., steam sterilization under pressure. A dry heat sterilizer operates with dry heat at different parameters, so it requires a dedicated dry heat indicator. If you use both types of sterilizers in your studio, you need a separate indicator for each.
How much tape do I use per cycle and how long does the roll last?▾
The instructions recommend one piece of about 4–5 cm (with at least 3 indicator lines) for each package, cassette, or instrument box. Even if you use generously, around 10–15 cm per package, the 50 m roll provides approximately 330–500 uses. For a tattoo studio with daily sterilizations, a single roll lasts for months.
On what types of packaging does the tape adhere?▾
The tape has its own adhesive and adheres to any type of wrapping: sterilization pouches, paper, and other packaging materials, as well as cassettes or instrument boxes. In addition to its role as an indicator, it also functions as an additional seal — you can immediately see if a package has been opened after sterilization.
Is the use of the indicator mandatory in a tattoo studio?▾
Yes. The use of sterilization indicators is a requirement of health regulations for tattoo and piercing studios that work with reusable instruments. The tape must be applied for every sterilization cycle, on every package placed in the autoclave, so that there is evidence that each batch of instruments has gone through the sterilization process.