Sterilization self-sealing bags for autoclave 150x250mm 10 pieces
Specifications
- Packaging
- 10 buc
- Material
- Transparent laminated film
- Dimensions
- 150x250mm
- Quantity
- 10 pieces
- Sterilization
- Autoclave, Ethylene Oxide
- Steam temperature
- 121-134 ºC
- Oxide temperature
- 30-54 ºC
- Sterilization duration
- 2 months
Ghiduri utile:Consumabile de tatuaj — lista completă și la ce folosescConsumabile pentru un studio de tatuaj: lista completă lunarăConsumabile de unică folosință pentru studioul de tatuaj: ghid complet
Presentation video
Guide & full description
Complete guide: Sterilization self-sealing bags for autoclave 150x250mm 10 pieces
These are self-sealing sterilization bags designed for autoclave — the combination of white medical paper and transparent laminated film allows you to see the instrument inside without opening the package. They are a basic consumable for any tattoo studio or clinic that sterilizes reusable instruments: grips, tubes, forceps, or needle sets. The 150x250 mm format is the most generous in the range, suitable for bulkier instruments, and the set contains 10 pieces.
How to use
- Clean and thoroughly dry the instruments before packaging — the bag does not replace prior cleaning, it preserves the sterility achieved in the autoclave.
- Insert the instrument into the bag open or disassembled, with sharp tips protected, so as not to perforate the packaging. Basic rule: one instrument per bag.
- Press the bag until all air is removed from inside.
- Peel off the foil from the adhesive strip and seal the open end airtight — no sealing machine needed.
- Place each package in the autoclave avoiding direct contact with the metal tray of the sterilizer.
- Run the steam sterilization cycle at 121–134 °C, maximum 30 minutes.
- Let the bags cool in the sterilizer for 5–10 minutes after the cycle; for faster cooling, leave the door wide open.
- Check the indicator impregnated in the paper: for steam sterilization the color must have changed from pink to brown. Only then store the package.
Tips from us
- Note the sterilization date on each bag (on the plastic film side or on the sealing flap, not on the paper above the instrument), so you always know when the 2-month period expires.
- Choose the bag size according to the instrument: the 150x250 mm format is suitable for large grips, tubes, and complete sets, but do not stuff multiple pieces into a single bag — sealing and steam penetration suffer.
- Store sterilized packages in a clean, dry place, protected from moisture — a wet or damaged bag no longer guarantees sterility of the contents.
- Open the bag by peeling apart the two layers (paper and film) just before use, not with scissors or by tearing, to remove the instrument without touching the outer edges.
- Check the indicator on each package, every cycle — if it has not changed color, the process did not run correctly and sterilization must be repeated with a new bag.
Frequently asked questions
Do I need a sealing machine to use these bags?▾
No. The bags have a special adhesive strip protected by a removable foil: after inserting the instrument and removing the air, you peel off the foil and press the strip, and the bag end seals airtight. This is exactly their advantage over classic sterilization rolls, which require a heat sealer.
How do I know if sterilization was successful?▾
The bags have two indicators impregnated in the paper. For steam sterilization in an autoclave at 121–134 °C, the indicator changes color from pink to brown. For ethylene oxide sterilization at 30–54 °C, the color changes from blue to orange. If the indicator has not changed after the cycle, treat the contents as non-sterile and repeat the process with a new bag.
How long do instruments remain sterile in the sealed bag?▾
Approximately 2 months after sterilization, provided the packaging remains intact, sealed, and stored properly in a clean, dry place. If the bag is perforated, peeled, or becomes wet in the meantime, sterility is no longer guaranteed — the instrument must be repackaged and sterilized again. That is why it is worth noting the sterilization date on each package.
What instruments fit in the 150x250 mm size and how do I choose the right size?▾
The 150x250 mm format is the most generous, suitable for bulkier instruments: large grips, tubes, forceps, and complete sets. The selection rule is simple: the instrument must fit easily, open or disassembled, with sharp tips protected, and the bag must be sealable without tension. The recommendation is one instrument per bag — this way steam penetrates evenly and you open exactly what you need, when you need it.
Can I reuse a bag if it looks intact after opening?▾
No. The bags are strictly single-use — once opened or passed through a sterilization cycle, they are discarded. The adhesive strip and material no longer ensure an airtight seal on second use, so sterility could no longer be guaranteed. At 10 pieces per set, the cost per sterilized instrument remains very low compared to the risk of contamination.
Do these bags work for other sterilization methods besides autoclave?▾
Yes, they are designed for two methods: steam sterilization in an autoclave (121–134 °C, maximum 30 minutes) and ethylene oxide sterilization (30–54 °C), each with its dedicated color indicator. They are not intended for other processes — for hot air sterilizers (Poupinel), for example, special packaging for dry heat is used, not this type of bag.