Sterilization self-sealing bags for autoclave 75x250mm 100 pieces
Specifications
- Packaging
- 100 buc
- Material
- Medical grade plastic
- Dimensions
- 75x250mm
- Quantity
- 100 pieces
- Sterilization
- Autoclave/Ethylene Oxide
- Steam temperature
- 121-134 ºC
- Oxide temperature
- 30-54 ºC
- Sterilization duration
- 2 months
Ghiduri utile:Consumabile de tatuaj — lista completă și la ce folosescConsumabile pentru un studio de tatuaj: lista completă lunarăConsumabile de unică folosință pentru studioul de tatuaj: ghid complet
Presentation video
Guide & full description
Complete guide: Sterilization self-sealing bags for autoclave 75x250mm 100 pieces
These are disposable bags for packaging instruments before autoclave sterilization, made from white medical paper on one side and transparent laminated film (polyester or polypropylene) on the other. The transparent side allows you to see the contents without opening the package, and the integrated adhesive strip seals the bag airtight without a sealing machine. They are an essential consumable for any tattoo studio or clinic that sterilizes reusable instruments — grips, forceps, tubes — and wants visual proof that sterilization was done correctly, through the color indicators impregnated in the paper.
How to use
- Clean and dry the instruments before packaging; articulated ones are placed open or disassembled, and sharp tips are protected to avoid perforating the bag.
- Insert a single instrument (or a single set intended for one use) into the 75x250mm bag — the elongated format is suitable for forceps, grips, narrow tubes, and thin instruments.
- Gently press the bag to remove all air from inside.
- Peel off the protective film from the adhesive strip and press firmly for an airtight seal across the entire width of the bag.
- Place the packages in the autoclave without directly touching the metal tray of the sterilizer and without tightly overlapping each other.
- Run the steam sterilization cycle at 121–134°C for a maximum of 30 minutes, according to your autoclave's instructions.
- Check the indicator on the paper: for steam sterilization the color must change from pink to brown (for ethylene oxide, from blue to orange). If it hasn't changed, the process is not validated — repeat sterilization with a new bag.
- Let the packages cool in the sterilizer for 5–10 minutes after the cycle; you can leave the door wide open to speed up cooling, then store them in a clean, dry place.
Tips from us
- Write the sterilization date on the plastic side of the bag (never on the paper) so you always know how old each package is.
- Use one bag per instrument — it's the basic feature of this type of packaging and guarantees that each piece remains sterile until you open it exactly when you need it.
- Choose the bag size according to the instrument: 75x250mm is the narrow and long format, ideal for forceps, grips, and tubes; instruments should not be forced inside, otherwise they risk perforating the packaging.
- Open the package only in front of the client, at the beginning of the session — it's also visible proof of the studio's professionalism.
- Store the sterilized bags away from moisture and objects that could perforate them; any wet, torn, or compromised seal bag is considered non-sterile.
- For a high workload, the pack of 100 pieces reduces the cost per sterilization — keep track of stock so you don't run out of bags between cycles.
Frequently asked questions
Do I need a sealing machine for these bags?▾
No. They are self-sealing bags: they have a special adhesive strip protected by a removable film. After inserting the instrument and removing the air, you peel off the film and press the strip — the closure is airtight without any additional equipment. This makes them practical even for small studios that don't want to invest in a roll sealing machine.
How do I know that sterilization really succeeded?▾
Each bag has two indicators impregnated in the medical paper: one for steam and one for ethylene oxide. During autoclave sterilization (121–134°C), the steam indicator changes from pink to brown; for ethylene oxide (30–54°C), from blue to orange. If the color hasn't changed after the cycle, sterilization is not validated — check the autoclave and repeat the process with a new bag.
What instruments fit in the 75x250mm size and how do I choose the right size?▾
The 75x250mm format (7.5 x 25 cm) is narrow and elongated, suitable for thin instruments: forceps, grips, narrow tubes. The selection rule: the instrument should fit easily without straining the bag, and articulated ones are packaged open or disassembled. If you have to force the instrument inside, move to a larger size — a strained bag can perforate and compromise sterility.
How long do instruments remain sterile after autoclaving?▾
According to product specifications, sterility is maintained for up to 2 months after sterilization, with the essential condition that the packaging remains intact, sealed, and properly stored (clean, dry place, protected from perforation). Any damaged or wet bag is considered non-sterile, regardless of the date. It's good practice to note the sterilization date on each package and follow the studio's internal protocol.
Can I reuse a bag if I haven't opened it, but it has gone through a cycle?▾
No. The bags are single-use: after one sterilization cycle they cannot be sterilized a second time, and once opened they are discarded. If the sterility maintenance period has expired or the packaging has deteriorated, the instrument is re-sterilized in a new bag.
Do they work in other types of sterilizers, for example a hot air oven (Poupinel)?▾
These bags are designed for steam sterilization in an autoclave, at 121–134°C for a maximum of 30 minutes, and are also compatible with ethylene oxide sterilization (they have a dedicated indicator for each method). They are not intended for other sterilization methods — use them only in the processes for which they have been approved, and in the autoclave avoid direct contact of the bags with the metal tray.