Sterilization self-sealing bags for autoclave 90x250mm 10 pieces

Cod produs: 320012
7,70 Lei
Fast delivery
Delivery 24-48h
14-day returnsWarrantyDelivery 24-48h
💵 Cash on delivery🔒 Secure order
Quick:
1

Specifications

Packaging
10 pcs
Dimensions
90x250mm
Quantity
10 pcs
Material
Transparent laminated film
Composition
Polyester/polypropylene and medical paper
Color
White
Sterilization
Autoclave/Ethylene Oxide
Sterility Shelf Life
2 months

Ghiduri utile:Consumabile de tatuaj — lista completă și la ce folosescConsumabile pentru un studio de tatuaj: lista completă lunarăConsumabile de unică folosință pentru studioul de tatuaj: ghid complet

Presentation video

Guide & full description

Complete guide: Sterilization self-sealing bags for autoclave 90x250mm 10 pieces

The 90x250mm self-sealing bags are the essential consumable for sterilizing and keeping reusable instruments sterile in a tattoo studio or clinic: grips, forceps, small scissors, or needle sets. They are made of medical paper on one side and transparent plastic film on the other, allowing steam to penetrate during the process, while after sterilization the package remains an airtight barrier. The set contains 10 pieces and you don't need any sealing machine: each bag has its own adhesive strip. They are compatible with both steam autoclave and ethylene oxide sterilization.

How to use

  1. Clean and thoroughly dry instruments before packaging - organic residues prevent proper sterilization. Open or disassemble articulated instruments (forceps, scissors) and protect sharp tips.
  2. Insert a single instrument (or a single set) into the bag. The rule is one product per bag, so you can open the sterile package exactly when needed.
  3. Press the bag to remove all air inside before sealing.
  4. Remove the protective film from the adhesive strip and press the open end along its entire length for an airtight seal.
  5. Place each package in the sterilizer, avoiding direct contact with the metal tray of the machine.
  6. Run the steam sterilization cycle at 121-134 °C, maximum 30 minutes (the product is approved for this range).
  7. Let the bags cool for 5-10 minutes in the sterilizer after the cycle ends; for faster cooling, you can leave the door wide open.
  8. Check the indicator before use: during steam sterilization the color changes from pink to brown (for ethylene oxide, from blue to orange). Keep the bag sealed until the moment of use.

Tips from us

  • Write the sterilization date on the bag to follow the order of use and control the package's validity.
  • Do not overload the bag: leave enough space at the adhesive strip end for proper sealing and air removal.
  • Store sterilized bags in a clean, dry place, protected from moisture and mechanical damage.
  • Check the indicator every time before opening a package - if the color hasn't changed, do not use the instrument, but resterilize it.
  • Open the bag by pulling from the end, do not puncture it, to keep the tip sterile; use the instrument immediately after opening.
  • Maintain a constant stock: as a daily consumable, a set of 10 pieces is quickly used up in an active studio.
Warning: Bags are single-use: once opened or used, they are discarded, as they cannot be sterilized a second time. Instruments must be cleaned and dried before packaging - sterilization does not clean dirt. The indicator only confirms that the package has been exposed to the sterilization process, it does not guarantee sterility on its own; this depends on a correct and complete autoclave cycle. Do not use any package if the packaging is damaged, wet, or unsealed - in this case, the instrument must be resterilized. Follow your studio's sanitary protocol; correct use of the bags is a mandatory requirement for compliance with hygiene standards.

Frequently asked questions

How does the self-sealing system work?

Each bag has an adhesive strip protected by a removable film. After inserting the instrument and removing the air, you peel off the film and press the adhesive strip along its entire length. It seals airtight without needing a separate sealing machine.

What does the indicator color change mean?

The bag has indicators impregnated in the paper that visually confirm the package has gone through the process. During steam sterilization at 121-134 °C, the color changes from pink to brown; during ethylene oxide sterilization at 30-54 °C, it changes from blue to orange. If the indicator has not changed, do not use the instrument.

What temperatures can they be used at?

They are approved for steam sterilization (autoclave) at 121-134 °C, for a maximum of 30 minutes per cycle, covering standard protocols in tattoo studios. They are also compatible with ethylene oxide sterilization at 30-54 °C.

How long do instruments remain sterile in the sealed bag?

Instruments remain sterile as long as the bag is intact, dry, and properly sealed. Follow the manufacturer's stated shelf life and your studio's internal protocol; if the packaging is damaged, becomes wet, or unsealed, resterilize the instrument before use.

What instruments fit in the 90x250mm size?

The 90x250mm (9.0x25.0 cm) size is suitable for medium-sized instruments such as standard grips, forceps, small scissors, and needle sets. For larger or longer instruments, choose a bag with appropriate dimensions.

Can I reuse a bag after opening it?

No. Self-sealing bags are single-use and are used for one product only. Once opened or used, they are discarded - they cannot be resterilized. Use a new bag for each sterilization cycle.

Product description

Sterilization self-sealing bags for autoclave The self-sealing bags are made of a plastic for medical use, called transparent laminated film, which comes from a special polyester or polypropylene film and medical paper. The paper used is smooth on both sides, white in color and provides great anti-bacterial protection. They are used for sterilization with Autoclave and Ethylene Oxide. To check the effectiveness of the sterilization, they have two indicators impregnated in the paper, one for steam and another for ethylene oxide. Correct sterilization is certified by changing the color of the indicator. For steam sterilization, at a temperature of 121-134 º C, the color changes from pink to brown. For sterilization with ethylene oxide, at a temperature of 30-54 º C, the color changes from blue to orange. The duration of maintaining sterilization is 2 months from sterilization, provided the integrity of the packaging is maintained. The bags used once must be thrown away, because they cannot be sterilized a second time. The distinctive feature of self-adhesive bags is their use for a single product. It does not require the use of a sealing machine, because it has a special adhesive tape that hermetically closes the open end of the bag. When using these bags, the instruments must be opened or dismantled, and the sharp points protected. This type of packaging provides protection for chemical and biological contamination from the moment of sterilization, until the package is opened.1. Insert the instrument into the bag and press until all the air is removed from the bag;2. Seal the bag;3. Place each package in the sterilizer. Avoid any contact with the metal tray of the sterilization oven (or with a bag in the case of the steam sterilization process);4. This product is approved / created for use in the steam sterilization process (autoclave sterilization) at temperatures of 121-134 º C for a maximum of 30 minutes.5. Let the bags / packages cool down in the sterilizer for 5-10 minutes after the whole process. To speed up cooling, leave the sterilizer door wide open; The price is for a set of 10 pieces. Size: 90x250mm Self-sealing sterilization pouches sized 90x250mm are essential consumables for any tattoo studio or medical office using autoclaves for reusable instrument sterilization. Made from high-grade medical paper on one side and transparent plastic film on the other, these pouches allow content visualization without opening, quickly identifying needed instruments. The self-sealing system guarantees an airtight and secure closure without requiring additional sealing equipment. The integrated sterilization indicator changes color after the autoclaving process, visually confirming proper sterilization. The 90x250mm size is versatile, suitable for medium-sized instruments such as standard grips, tweezers, small scissors, and needle sets. The package contains 10 pieces, being ideal for daily studio use. Materials used comply with European sterilization standards and are compatible with steam autoclaves at temperatures up to 134 degrees Celsius. The pouches maintain instrument sterility for an extended period after autoclaving, as long as the packaging remains intact and sealed. Proper use of self-sealing pouches is a mandatory requirement for sanitary compliance and demonstrates the studio's professionalism toward client health. The medical paper on one side allows steam penetration during autoclaving, while the transparent plastic film on the other side ensures a sterile barrier after sterilization. This dual design is essential for sterilization process efficacy and long-term sterility maintenance. Frequently Asked Questions How does the self-sealing system work? The pouches have an adhesive strip protected by a peel-off film. After inserting instruments, remove the film and press the adhesive strip for an airtight, secure seal without additional equipment. What does the indicator color change indicate? The sterilization indicator changes color from light to dark after exposure to steam at the correct temperature, visually confirming the autoclaving process was properly performed. At what temperatures can they be used? The pouches are compatible with steam autoclaves at temperatures up to 134 degrees Celsius, covering all standard sterilization protocols used in tattoo studios. How long do instruments remain sterile in the sealed pouch? Instruments remain sterile as long as the pouch is intact and properly sealed. Under optimal storage conditions, sterility is maintained for up to 30 days. What instruments can be sterilized in the 90x250mm size? The 90x250mm size (9.0x25.0 cm) is suitable for instruments such as grips, tweezers, tubes, and needles. Choose the size based on instrument volume. Are they single-use? Yes, self-sealing pouches are strictly single-use. After opening the seal, the pouch must be discarded and instruments re-sterilized in a new pouch if not used immediately. Can I see the contents without opening the pouch? Yes, one side of the pouch is transparent plastic film allowing visualization of instruments inside without compromising sterility by opening. Are they compliant with European standards? Yes, the self-sealing pouches are manufactured according to European sterilization standards and approved for use in professional medical and cosmetic environments. How should unused pouches be stored? Store unused pouches in a dry place at room temperature, away from direct light and humidity. Avoid damaging the original packaging to maintain quality. Can they be used in fields other than tattooing? Yes, self-sealing pouches are universal and used in dental offices, cosmetic salons, micropigmentation, podiatry, and any field requiring instrument sterilization.